    "document": {
        "acknowledgments": [
            {
                "organization": "CERT@VDE",
                "summary": "coordination",
                "urls": [
                    "https://certvde.com"
                ]
            }
        ],
        "category": "csaf_security_advisory",
        "csaf_version": "2.0",
        "distribution": {
            "tlp": {
                "label": "WHITE",
                "url": "https://www.first.org/tlp/"
            }
        },
        "lang": "en-GB",
        "notes": [
            {
                "category": "summary",
                "text": "A vulnerability is reported in WIBU-SYSTEMS Codemeter. WIBU-SYSTEMS Codemeter is installed by default during e!COCKPIT and WAGO-I/O-Pro (CODESYS 2.3) installations. All currently existing e!COCKPIT installation bundles and WAGO-I/O-Pro (CODESYS 2.3) installation bundles are affected with vulnerable versions of WIBU-SYSTEMS Codemeter.",
                "title": "Summary"
            },
            {
                "category": "description",
                "text": "WAGO controllers and IO-Devices are not affected by WIBU-SYSTEMS Codemeter vulnerabilities. However, due to compatibility reasons to the CODESYS Group CODESYS store, the e!COCKPIT and engineering software is bundled with a WIBU-SYSTEMS Codemeter installation.",
                "title": "Impact"
            },
            {
                "category": "description",
                "text": "- Use general security best practices to protect systems from local and network attacks.\n- Disable the container type 'Mass Storage' in CodeMeter via the Windows Registry.",
                "title": "Mitigation"
            },
            {
                "category": "description",
                "text": "We strongly encourage e!COCKPIT and WAGO-I/O-Pro (CODESYS 2.3) users to update WIBU-SYSTEMS Codemeter by installing the latest available stand-alone WIBU-SYSTEMS Codemeter Version.\n\nWAGO will provide updated e!COCKPIT setup routines (Version 1.11) with the latest WIBU- SYSTEMS Codemeter version in Q2/2022.\n\nAdditionally WAGO will provide a security patch for e!COCKPIT Version 1.10 in February 2022.\nWAGO will provide updated WAGO-I/O-Pro (CODESYS 2.3) (Version 2.3.9.68) setup routines with the latest WIBU-SYSTEMS Codemeter version in Q1/2022.\n\nFor further details on risk mitigation and impact of this vulnerability, please refer to the official WIBU-SYSTEMS Advisory WIBU-210910-01 at Website https://www.wibu.com/support/security-advisories.html external link.\n\nFurther details on the corresponding CVEs can be obtained here:\nhttps://cdn.wibu.com/fileadmin/wibu_downloads/security_advisories/Advisory_WIBU-210910-01.pdf external link",
                "title": "Remediation"
            }
        ],
        "publisher": {
            "contact_details": "psirt@wago.com",
            "name": "WAGO GmbH & Co. KG",
            "namespace": "https://www.wago.com/psirt",
            "category": "vendor"
        },
        "references": [
            {
                "category": "self",
                "summary": "VDE-2022-002: WAGO: Vulnerable WIBU-SYSTEMS Codemeter installed through e!COCKPIT and WAGO-I/O-Pro - HTML",
                "url": "https://certvde.com/en/advisories/VDE-2022-002/"
            },
            {
                "category": "self",
                "summary": "VDE-2022-002: WAGO: Vulnerable WIBU-SYSTEMS Codemeter installed through e!COCKPIT and WAGO-I/O-Pro - CSAF",
                "url": "https://wago.csaf-tp.certvde.com/.well-known/csaf/white/2022/vde-2022-002.json"
            },
            {
                "category": "external",
                "summary": "Vendor PSIRT",
                "url": "https://www.wago.com/psirt"
            },
            {
                "category": "external",
                "summary": "CERT@VDE Security Advisories for WAGO GmbH & Co. KG",
                "url": "https://certvde.com/en/advisories/vendor/wago/"
            }
        ],
        "title": "WAGO: Vulnerable WIBU-SYSTEMS Codemeter installed through e!COCKPIT and WAGO-I/O-Pro",
        "tracking": {
            "aliases": [
                "VDE-2022-002"
            ],
            "current_release_date": "2025-05-22T13:03:10.000Z",
            "generator": {
                "date": "2025-04-28T08:43:49.504Z",
                "engine": {
                    "name": "Secvisogram",
                    "version": "2.5.24"
                }
            },
            "id": "VDE-2022-002",
            "initial_release_date": "2022-01-31T13:00:00.000Z",
            "revision_history": [
                {
                    "date": "2022-01-31T13:00:00.000Z",
                    "number": "1",
                    "summary": "Initial revision."
                },
                {
                    "number": "2",
                    "summary": "Fix: quotation mark",
                    "date": "2025-05-22T13:03:10.000Z"
                }
            ],
            "status": "final",
            "version": "2"
        }
    },
    "product_tree": {
        "branches": [
            {
                "name": "WAGO",
                "category": "vendor",
                "branches": [
                    {
                        "name": "Software",
                        "category": "product_family",
                        "branches": [
                            {
                                "name": "WAGO e!COCKPIT engineering software installation bundle",
                                "category": "product_name",
                                "branches": [
                                    {
                                        "name": "<V1.11",
                                        "category": "product_version_range",
                                        "product": {
                                            "name": "WAGO e!COCKPIT engineering software installation bundle <V1.11",
                                            "product_id": "CSAFPID-51001"
                                        }
                                    },
                                    {
                                        "name": "V1.11",
                                        "category": "product_version",
                                        "product": {
                                            "name": "WAGO e!COCKPIT engineering software installation bundle V1.11",
                                            "product_id": "CSAFPID-52001"
                                        }
                                    }
                                ]
                            },
                            {
                                "name": "WAGO-I/O-Pro (CODESYS 2.3) engineering software installation",
                                "category": "product_name",
                                "branches": [
                                    {
                                        "name": "2.3.9.53",
                                        "category": "product_version",
                                        "product": {
                                            "name": "WAGO-I/O-Pro (CODESYS 2.3) engineering software installation 2.3.9.53",
                                            "product_id": "CSAFPID-51002"
                                        }
                                    },
                                    {
                                        "name": "2.3.9.68",
                                        "category": "product_version",
                                        "product": {
                                            "name": "WAGO-I/O-Pro (CODESYS 2.3) engineering software installation 2.3.9.68",
                                            "product_id": "CSAFPID-52002"
                                        }
                                    },
                                    {
                                        "name": "2.3.9.55",
                                        "category": "product_version",
                                        "product": {
                                            "name": "WAGO-I/O-Pro (CODESYS 2.3) engineering software installation 2.3.9.55",
                                            "product_id": "CSAFPID-51003"
                                        }
                                    },
                                    {
                                        "name": "2.3.9.61",
                                        "category": "product_version",
                                        "product": {
                                            "name": "WAGO-I/O-Pro (CODESYS 2.3) engineering software installation 2.3.9.61",
                                            "product_id": "CSAFPID-51004"
                                        }
                                    },
                                    {
                                        "name": "2.3.9.66",
                                        "category": "product_version",
                                        "product": {
                                            "name": "WAGO-I/O-Pro (CODESYS 2.3) engineering software installation 2.3.9.66",
                                            "product_id": "CSAFPID-51005"
                                        }
                                    },
                                    {
                                        "name": "2.3.9.46",
                                        "category": "product_version",
                                        "product": {
                                            "name": "WAGO-I/O-Pro (CODESYS 2.3) engineering software installation 2.3.9.46",
                                            "product_id": "CSAFPID-51006"
                                        }
                                    },
                                    {
                                        "name": "2.3.9.49",
                                        "category": "product_version",
                                        "product": {
                                            "name": "WAGO-I/O-Pro (CODESYS 2.3) engineering software installation 2.3.9.49",
                                            "product_id": "CSAFPID-51007"
                                        }
                                    },
                                    {
                                        "name": "2.3.9.47",
                                        "category": "product_version",
                                        "product": {
                                            "name": "WAGO-I/O-Pro (CODESYS 2.3) engineering software installation 2.3.9.47",
                                            "product_id": "CSAFPID-51008"
                                        }
                                    }
                                ]
                            }
                        ]
                    }
                ]
            }
        ],
        "product_groups": [
            {
                "group_id": "CSAFGID-0001",
                "product_ids": [
                    "CSAFPID-51001",
                    "CSAFPID-51002",
                    "CSAFPID-51003",
                    "CSAFPID-51004",
                    "CSAFPID-51005",
                    "CSAFPID-51006",
                    "CSAFPID-51007",
                    "CSAFPID-51008"
                ],
                "summary": "Affected products."
            },
            {
                "group_id": "CSAFGID-0002",
                "product_ids": [
                    "CSAFPID-52001",
                    "CSAFPID-52002"
                ],
                "summary": "Fixed products."
            }
        ]
    },
    "vulnerabilities": [
        {
            "cve": "CVE-2021-41057",
            "cwe": {
                "id": "CWE-59",
                "name": "Improper Link Resolution Before File Access ('Link Following')"
            },
            "notes": [
                {
                    "category": "description",
                    "text": "In WIBU CodeMeter Runtime before 7.30a, creating a crafted CmDongles symbolic link will overwrite the linked file without checking permissions.",
                    "title": "Vulnerability Description"
                }
            ],
            "product_status": {
                "fixed": [
                    "CSAFPID-52001",
                    "CSAFPID-52002"
                ],
                "known_affected": [
                    "CSAFPID-51001",
                    "CSAFPID-51002",
                    "CSAFPID-51003",
                    "CSAFPID-51004",
                    "CSAFPID-51005",
                    "CSAFPID-51006",
                    "CSAFPID-51007",
                    "CSAFPID-51008"
                ]
            },
            "remediations": [
                {
                    "category": "mitigation",
                    "details": "Mitigation\n\nUse general security best practices to protect systems from local and network attacks.\nDisable the container type 'Mass Storage' in CodeMeter via the Windows Registry.",
                    "group_ids": [
                        "CSAFGID-0001"
                    ]
                },
                {
                    "category": "vendor_fix",
                    "details": "We strongly encourage e!COCKPIT and WAGO-I/O-Pro (CODESYS 2.3) users to update WIBU-SYSTEMS Codemeter by installing the latest available stand-alone WIBU-SYSTEMS Codemeter Version.\nWAGO will provide updated e!COCKPIT setup routines (Version 1.11) with the latest WIBU- SYSTEMS Codemeter version in Q2/2022.\nAdditionally WAGO will provide a security patch for e!COCKPIT Version 1.10 in February 2022.WAGO will provide updated WAGO-I/O-Pro (CODESYS 2.3) (Version 2.3.9.68) setup routines with the latest WIBU-SYSTEMS Codemeter version in Q1/2022.\nFor further details on risk mitigation and impact of this vulnerability, please refer to the official WIBU-SYSTEMS Advisory WIBU-210910-01 at Website https://www.wibu.com/support/security-advisories.html.\nFurther details on the corresponding CVEs can be obtained here:https://cdn.wibu.com/fileadmin/wibu_downloads/security_advisories/Advisory_WIBU-210910-01.pdf",
                    "group_ids": [
                        "CSAFGID-0001"
                    ]
                }
            ],
            "scores": [
                {
                    "cvss_v3": {
                        "attackComplexity": "LOW",
                        "attackVector": "LOCAL",
                        "availabilityImpact": "HIGH",
                        "baseScore": 7.1,
                        "baseSeverity": "HIGH",
                        "confidentialityImpact": "NONE",
                        "environmentalScore": 7.1,
                        "environmentalSeverity": "HIGH",
                        "integrityImpact": "HIGH",
                        "privilegesRequired": "LOW",
                        "scope": "UNCHANGED",
                        "temporalScore": 7.1,
                        "temporalSeverity": "HIGH",
                        "userInteraction": "NONE",
                        "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:H",
                        "version": "3.1"
                    },
                    "products": [
                        "CSAFPID-51001",
                        "CSAFPID-51002",
                        "CSAFPID-51003",
                        "CSAFPID-51004",
                        "CSAFPID-51005",
                        "CSAFPID-51006",
                        "CSAFPID-51007",
                        "CSAFPID-51008"
                    ]
                }
            ],
            "title": "CVE-2021-41057"
        }
    ]
}